  • NUT UPS, howto shut down client after 2 min on battery?
    Internet has told me that SHUTDOWNCMD “ sbin shutdown -h +0” in etc nut upsmon conf will execute when the UPS is both OB (on battery) and LB (Low battery) Like in wiki ipfire org - Detailed NUT Configuration where it says “SHUTDOWNCMD “ sbin shutdown -h +0” this command will be triggered if UPS sends the BL (Battery Low) flag
  • 6. Configuration notes - Network UPS Tools
    In order for this to work, you need to shutdown NUT (UPS driver, upsd server and upsmon client) in the suspend script and start them again in the resume script Don’t try to keep them running The upsd server will latch the FSD state (so it won’t be usable after resuming) and so will the upsmon client Some drivers may work after resuming
  • shutdown procedure - when is the power off for the outlet triggered
    To have the outlet groups power off 15 minutes after the OS is commended down in PCNS under Shutdown Settings select Turn off UPS Then in the NMC web interface set the outlet off delay to 900 seconds
  • NUT shutdown script does not run when UPS switches to battery power . . .
    The main problem was that the nut user had no permission to run the shutdown command So, as sudo is installed on the system, I've just created a custom permission for this purpose: sudo visudo etc sudoers d nut
  • Nut command to shutdown pfsense after specified amount of time
    The nut manual says set ups delay start (default 30) as the interval to wait before restarting the load (seconds) [after UPS power returns] CyberPower UPSs restart ups delay start seconds after the UPS shutdown commences, regardless of the wall power status
  • Network UPS Tools (NUT) configuration files and scripts to shutdown . . .
    The idea from this is to provide a graceful shutdown to NetApp ONTAP What this setup will do: The NUT server will monitor the state of the UPS When power is lost and UPS is on battery, start a timer for 3 minutes If power comes back and UPS is back online, cancel the above timer
  • Modifying NUT UPS shutdown delay. - Koozali
    I would like to change the configuration so that the server will shut down 2 minutes after receiving the "on battery" signal What is the best way to achieve this? Thanks in advance
  • NUT shuts down UPS even when power is available - Server Fault
    when the UPS powers back on having a low battery (i e runtime < battery runtime low) and turns on the load, it immediately triggers a FSD and none of the devices have time to properly shut down, as the Pi master shuts everything down again
  • UPS is not powering off on command - #57 by rymandle05 - TrueNAS . . .
    Shutdown Command: bin midclt call system shutdown This should ensure TrueNAS shuts down properly and was recently talked about the TrueNAS Tech Talk Podcast UPS should now operate as expected with UPS shutting down after 90 seconds and powering back on when power is restored
  • Help with Home Assistant Automation for UPS Shutdown Sequence
    I’m trying to set up an automation in Home Assistant that triggers a shutdown sequence for my devices when my UPS goes into battery mode (ONBATT) I want to ensure that the automation only executes if the power outage lasts for 10 seconds